Diagnostic ECG

PageWriter TC70

Cardiograph

Product number:

860315

Philips PageWriter TC70 cardiograph is designed to simplify diagnostic ECG testing and streamline workflow – where an automated workflow and outstanding clinical support is critical.

Kontaktinformation

* Detta fält är obligatoriskt
*

Kontaktuppgifter

*
*
*

Företagsinformation

*
*
*
*
*

Kommunikationsdetaljer

Genom att specifiera anledningen till att du kontaktar oss, kan vi ge dig en bättre service
*
*
Features
Visual guidance || Advanced, yet easy to use

Visual guidance to simplify ECGs

With the PageWriter TC70 cardiograph, each button lights in sequence, prompting you to take an ECG as easily as 1-2-3. The high-resolution, 15" touchscreen further streamlines ECGs.
Philips DXL ECG Algorithm || Superb clinical decision suppo

Philips DXL ECG Algorithm expands diagnostic capabilities

Philips DXL 16-Lead ECG Algorithm provides industry-leading ECG interpretations and a suite of advanced STEMI diagnostic aids to provide an interpretation of rhythm and morphology for a wide variety of patient populations. It includes: Critical Values, ST Maps, and culprit artery identification.
Automated reporting sequence || Automated workflow

Automated reporting sequence saves time

The high performance PageWriter TC70 cardiograph features an automated ECG report sequence with integrated wireless transfer of ECGs to streamline your workflow.
Lead placement aids || Advanced, yet easy to use

Lead placement aids accurate placement of leads on the patient

The anatomic patient interface module and LeadCheck help support correct lead placement, while the 3-in-1 Trident lead wires reduce tangling.
Critical Value statements || Superb clinical decision suppo

Critical Value statements speed the delivery of urgent care

When appropriate, the PageWriter TC70 automatically displays Critical Value summary statements boldly on screen and on printed ECG reports so that caregivers can determine the need for urgent care. Clinicians can quickly take action and reduce the time from the discovery of a critical cardiac event to intervention, such as balloon angioplasty.
Saved ECGs || Automated workflow

Saved ECGS can be quickly accessed

Clinicians can save time by retrieving previous ECGs at the bedside for quick comparisons.
Advanced bidirectional network commun... || Advanced, yet easy to use

Advanced bidirectional network communication for secure connection

With industry standardized DICOM, XML, and PDF report formats, via wireless LAN, or modem and fax, PageWriter TC70 fits seamlessly into your existing IT infrastructure. So you’re always connected, without being locked in. It delivers secure, wireless connectivity via standard LAN protocols to protect the privacy of patient, staff, and financial information.

Specifications Visa mer

Environmental
Operating Conditions (b)
15% to 80% relative humidity %
Operating Conditions (a)
10°C to 40°C (50°F to 104°F)
Operating Conditions (c)
Up to 4,550 m (15000 ft)
ECG Functions
Simultaneous Lead Acquisition
Up to 18 leads
Full Disclosure
Twenty minute history of all 16 leads and complete ECG report of any 10 seconds
Timed ECG
Support for pharma stress protocols
Report Storage/Transfer
Full fidelity at 500 Hz of all 10 sec for up to 16 leads in XML format (schema published)
Electrical
Battery recharge
5 hours to full capacity
Power consumption
75 W max W
Battery capacity
Typically 50 ECGs on a single charge
AC power
100-240 VAC at 50/60 Hz
Philips DXL 18-Lead ECG Algorithm
Interpretive statements
<gt/>600 interpretive statements with integrated pediatric analysis
LeadCheck
Lead placement software detects 20 different lead reversals
Borderline Statement Suppression
Three configurable settings
Reasons
Selectable explanations of all interpretive statements
Nomenclature
Conforms to 2007 AHA/ACC recommendations
STEMI Diagnostic Aids
Graphical ST Vector
Two polar ST Maps in frontal and transverse planes
Critical Values
Highlights 4 conditions requiring immediate clinical attention
User Interface
Touchscreen
1-2-3 operation/context sensitive application/5-wire resistive touchscreen
Keyboard
65 button standard full alphanumeric keyboard that supports special characters
Display
15 inch TFT
Networked Features (requires IntelliSpace ECG)
Central Time Management
Time can be synchronized to a networked time master
Orders
Configurable rules to retrieve cardiograph-specific worklists
Signal Quality Indicators
Leads Off Advisory
Anatomical lead map displays the location and label of any loose or disconnected leads/electrodes
Lead Color
Four colors to indicate levels of waveform quality
LeadCheck
Lead placement software detects 20 different lead reversals
Heart Rate
Continuous display of patient heart rate
Print Preview
Full screen preview of complete 16 lead report prior to printing
Training
Application Help
Integrated graphical HELP screens for primary functions
Self Paced
Computerized, interactive, dynamic animation covering all major clinical functionalities
Signal Processing
Patient Interface Module
Remote microprocessor-controlled digital module provides 5μV resolution
Pre-Processing Filters
AC Noise
50 to 60 Hz
Signal Processing
Artifact Rejection and Baseline Wander
Presentation Filters - 10 sec Reports
Low Pass
40/100/150 Hz
High Pass
0.05/0.15/0.5 Hz
Presentation Filters - Rhythm
High Pass
0/05/0.15 Hz
Presentaton Filters - Rhythm
Low Pass
40/100/150 Hz
Mechanical
Dimensions
40 x 33 x 16 cm (15.7 x 13 x 63 in)
Weight
13 kg/28 lb
Safety and Performance
International Standards
IEC 60601-1: 1988 +A1:1991 +A2:1995 General Requirement for Safety
IEC 60601-1: 1988 +A1:1991 +A2:1995 General Requirement for Safety
C 60601-2-51: 2003: Particular Requirements for Safety
Ul 2601-1: 20031997 US General Requirements for Safety
CAN/CSA-C22,2 No, 60l1-M90 51:1994 B:1996
AAMI EC111991 (R: 2001): Diagnostic Electrocardiography Devices